Product Overview
Mining Safety Voice Alarm Device is an industrial audio communication system for underground and open-pit mines, providing real-time safety alerts, operational dispatch, and personnel communication in remote or high-risk mining environments.
Features
Multi-Mode Alerts
Switches between safety warning, work dispatch, and training modes, replacing multiple devices and reducing operational costs.
System Integration
Automatically triggers alarms from monitoring, personnel tracking, and environmental sensors, with real-time feedback to control terminals for faster response.
Shockproof Design
Enclosure withstands vibrations and impacts in underground and open-pit mining, ensuring long-term stability.
Low Maintenance
Core components require up to 60% less maintenance than traditional units, reducing downtime and labor costs.
Main Technical Parameters
Explosion-proof Type: Exd[ib]I Mb
Rated Operating Voltage: 127 V AC
Rated Operating Current: ≤500 mA
Intrinsically Safe Power Supply Maximum Output Voltage (Uo): 12.5 V DC
Intrinsically Safe Power Supply Maximum Output Current (Io): 550 mA
Audible Alert Mode: Voice prompt, with distortion ≤ 15%
Alarm Voice Prompt Sound Level: ≥85 dB(A)
Visual Signal from Alarm: Clearly visible within 20 meters in dark environments
Opto-isolator Withstand Voltage: ≥1500 V
Speaker Type: Waterproof externally magnetic type, 8Ω / 5W
Operating Environment
Altitude not exceeding 1000 m (Atmospheric pressure: 80 ~ 106 kPa)
Ambient Temperature: 0°C ~ +40°C
Relative Humidity: ≤95% (at 25°C)
Suitable for hazardous locations with potentially explosive mixtures of methane and coal dust
Locations without corrosive gases or vapors sufficient to damage metals and electrical insulation materials
Locations without severe impact or vibration
Locations free from water dripping
Fault Causes And Troubleshooting
|
No. |
Fault Phenomenon |
Cause Analysis |
Remedy |
|
1 |
No display when powered on |
No 127V power supply or blown fuse |
Check power supply or replace fuse |
|
2 |
Partial LED indicators extinguished |
Damaged LEDs |
Replace LEDs |
|
3 |
No audible voice signal |
Damaged speaker Damaged voice circuit |
Replace speaker Replace main control board |
Customization Services
Multi-Mode Configuration
Adjust safety alert, work dispatch, and training modes to match specific mine management requirements.
Network and System Integration
Tailor connectivity to existing monitoring, personnel tracking, and environmental systems for seamless operation.
Power Supply Options
Customize solar, battery, or hybrid power setups to suit remote or electricity-limited sites.
Alert Protocols
Set custom audio levels, alarm sequences, and notification priorities according to site safety standards.
Factory Advantages
Wide Market Coverage
Used in major Chinese mining regions including Shandong, Inner Mongolia, Shaanxi, Shanxi, Ningxia, Xinjiang, Guizhou, and Gansu.
Full-Service Support
Comprehensive pre-sales and after-sales support helps customers optimize installation, operation, and maintenance.
Bulk Supply Ready
Capable of fulfilling large orders, meeting the needs of wholesale and repeat customers efficiently.
Certifications
Mining safety, explosion-proof, and CCC certified; all units undergo rigorous functional and safety testing.
FAQ
Hot Tags: mining safety voice alarm, China mining safety voice alarm manufacturers, suppliers, factory, Mining Safety Voice Alarm, mining sensor, mining voice and visual audible alarm systems